Bionet CardioCare2000

Product ID: BCC-2000    Category: Cardiology-EKG / ECG
BIONET - CardioCare2000

Description:  The CardioCare2000 is the most economically priced 12-channel resting ECG, but it does not compromise performance. It is suitable for routine use in private check, ER, or hospitals. The CardioCare2000's design maximizes user convenience with A4 size paper and one body type. Another special characteristic is the option to upgrade. The upgrade option allows the CardioCare2000 to be connected to network systems such as fax and PC (RS-232 or LAN).

Standard Accessories
·
Power Cable (1 each)
· Patient Cable (1 each)
· Electrode (10 each)
· Chart Paper (1 each)
· Operation Manual (1 each)

Optional Accessories
·
Rechargeable Battery (NiMH)
· Cart
· Hanger
· Bag
· PC s/w
· Limb electrode
· Chest electrode
· RS-232C null cable
· LAN cable (Ethernet-RJ-45)

ECG Leads

12-lead simultaneous 10-second resting

Dimesions

11.65 x 12.03 x 3.64 inches (6.57 pounds)

Recording Channel

3-, 6-, and 12-channnel. 1 channel (60 sec)

Sensitivity

5, 10, 20, auto (I-aVF:10, V1-V6:5)mm/mv

Printing Speed

12.5, 25, and 50 mm/s

Filters

AC: 50/60 Hz, -20 dB (or better)
Muscle: 25-35 Hz, -3 dB (or better)
Base line drift: 0.1 Hz, -3 dB (or better)
Low pass filter: off, 40 Hz, 100 Hz, or 150 Hz

Display
LCD Display
LED Indicator 

2 x 16 charachter LCD display
Sensitivity, speed, filter status, HR, print form, rhy. lead
Signal quality, power source, battery

Keyboard

Membrane keyboard, alphanumeric and symbol avail.

Patient Data
Basic Measurement

ID, name, age, sex, height, weight
HR, PR QRS QT/QTc, P-R-T axis

Recorder

Thermal print head, thermal roll paper
Report papers: 8 1/2 x 11 inches
Effective writing width: 8.03 inches
Resolution: 8 dots/mm (vert.), 16 dots/mm (horiz.)

Electrical

Internal noise: 20uV (p-p) max
Input circuit: floating input
Isolated and defibrillation protected
Input impedance: greater than or equal to 10 Mohms
Input range: greater than or equal to ±5 mV
Common mode rejection: greater than or equal to +100dB
DC offset voltage: greater than or equal to ±300
Time constant: 3.2 s
Patient leaskage current: less than 10uA
Frequency response: 0.05-150 Hz

Signal Quality Control

Disconnected lead detection

Power

Power supply: AC or built-in battery (option)
Power requirement: 100-240 Vac, 50/60 Hz, 1.0-0.5 A

Battery Capacity

1 hour of normal use (~100 automatic ECG printouts)

Communication

PC connection with RS-232 interface and LAN

Safety
Conformity

Class 1, Type BF
CE, CSA

Environment

Operating humidity: 30-85%
Operating temperature: 50-104ºF (10-40ºC)
Operating pressure: 70-106 kPa

 

 

Bionet CardioCare2000