Zoll PD 1600P Specifications

General                  

Size: 10.7 cm high x 33.5 cm wide x 37.4 cm deep (4.2 x 13.2 x 14.7 in).  Weight: 5.9 kg (13 lbs) with PD 4400 multifunction cable; 7.3 kg (16 lbs) with powercharger attached.

Pacemaker             

Type: VVI demand; asynchronous (fixed rate) when used without ECG leads.  Pulse type: rectilinear, constant current.  Pulse duration: 40 msecs.  Pulse amplitude: variable to 140 mA.  Pacing rate: variable from 30 to 180 PPM.  Output protection: fully defibrillator-protected and isolated.

Defibrillator          

Waveform: damped sinusoid.  Output energy delivered: selectable at 2, 3, 5, 7, 10, 20, 30, 50, 100, 150, 200, 300, 360 joules.  Energy selection: control on sternum paddle and front panel.  Charge time: less than 10 seconds.  Synchronized mode: synchronizes defibrillator pulse to patent’s R-wave.  “SYNC” message displayed on monitor.  Marker on monitor and on recorder paper identifies R-wave.  Charge controls: control on apex paddle and on front panel.  Paddles (optional): optional paddles are anterior/anterior adult and pediatric.  Adult paddles slide off to expose pediatric paddles.  Integral defibrillator tester: integral circuitry allows complete test of defibrillator charge and discharge without removing paddles from storage wells.  Identical circuitry allows complete test of unit configured with multifunction cable.  Defibrillation advisory: evaluates electrode connection and patient ECG to determine if defibrillation is required.  Shockable rhythms: ventricular fibrillation with amplitude> 150µV and wide QRS complex ventricular tachycardia with arętes greater than 150 bpm.

Recorder                

Paper: standard 40 mm thermal (grid width), 50 mm (paper width).  Speed: 25 mm/sec.  Delay: 6 seconds.  Annotations: time, date, defib energy, heart rate, pacer output, QRS sync marker, ECG size, lead, alarm, defib test Ok/fail, analyze ECG, shock advised, no shock advised, ECG too large/adjust gain.  Printout modes: manual or automatic.  Control: front panel or paddle

Batteries                

Type: rechargeable, sealed acid.  Recharge time: 4 hours or less with standard ZOLL powercharger.  Low battery indicator: message display on monitor with audible tone.  Approximately 20 minutes of monitoring remain when message is displayed.  Operating time: with a new fully charged battery – 35 defibrillator charges to maximum energy (360J), or 2.5 hours minimum.  3 hours typical of continuous monitoring, or 2.5 hours of continuous monitoring/pacing at 60 mA, 80 beats/min.

Monitor / Display  

Patient connection: via 3-lead ECG cable, paddles, and electrodes.  Selectable by front switch.  Input protection: fully defibrillator-protected.  Special circuit prevents distortion of ECG by pacer pulse.  Implanted pacemaker spike display: dedicated circuitry detects most implanted pacemaker spikes and provides standard display marker of spike on ECG trace.  Electrical isolation and shielding: input protected against high voltage defibrillator pulses and typical radio frequency interference.  Screen type and size: high-resolution CRT display, 4.5” diagonally (56 mm x 86 mm, viewing area).  Heart rate: digital display on monitor 0-300 bpm.  Pacer output current: digital display on monitor 0-140 mA.  Alarm On/Off status: display on monitor, user selectable, high – 60 to 280 bpm; low – 20 to 100 bpm.  Message display on monitor: ECG lead off, pacer electrode off, defibrillator paddle fault or electrode fault, recorder paper out, low battery voltage.

Zoll PD 1600P portable defibrillators